39 research outputs found

    Wireless point-of-care ultrasound: First experiences with a new generation handheld device

    Get PDF
    AIM: To evaluate the diagnostic reliability of a new generation wireless point-of care ultrasound device for abdominal and thoracic findings. MATERIAL AND METHODS: 40 patients (16 females, 24 males 19 –80 years, on average 56.1 years) were scanned by an experienced examiner using the new wireless Vscan Air device for abdominal and thoracic findings. The probe frequencies were 2–5 MHz (convex probe) and 3–12 MHz for the linear probe. As a reference standard, all patients were also examined using high-end ultrasound (LOGIQ E9/LOGIQ E10). Results were interpreted independently by two examiners in consensus, also with regard to the image quality (0–4, from not assessable = 0, to excellent 4). RESULTS: In all 40 patients (100%) examination with conventional high-end ultrasound and the Vscan Air ultrasound device was feasible. Sensitivity, specificity, positive and negative predictive value for the diagnosis of abdominal and thoracic findings were 63.3%, 100%, 100%, and 40%, respectively. Most main diagnostic findings were detected using the mobile device compared to the high-end ultrasound. Limitations were found regarding characterization and classification of hepatic and renal tumorous lesions. Image quality revealed mostly minor diagnostic limitations for the mobile device, mean 2.9 (SD ± 0.300) and was excellent or with only minor diagnostic limitations for conventional high-end ultrasound, mean 3.25 (SD ± 0.438). CONCLUSION: Due to its easy application and its high diagnostic reliability, point-of-care ultrasound systems of the latest generation represent a valuable imaging method for the primary assessment of abdominal and thoracic findings, especially in patients on intensive care units or in emergency situations

    Influence of hepatic fibrosis and inflammation: Correlation between histopathological changes and Gd-EOB-DTPA-enhanced MR imaging

    Get PDF
    Objective To evaluate the influence of an active inflammatory process in the liver on Gd-EOB-DTPA-enhanced MR imaging in patients with different degrees of fibrosis/cirrhosis. Material and methods Overall, a number of 91 patients (61 men and 30 women; mean age 58 years) were included in this retrospective study. The inclusion criteria for this study were Gd-EOB-DTPA-enhanced MRI of the liver and histopathological evaluation of fibrotic and inflammatory changes. T1-weighted VIBE sequences of the liver with fat suppression were evaluated to determine the relative signal change (RE) between native and hepatobiliary phase (20 min). In simple and multiple linear regression analyses, the influence of liver fibrosis/cirrhosis (Ishak score) and the histopathological degree of hepatitis (Modified Hepatic Activity Index, mHAI) on RE were evaluated. Results RE decreased significantly with increasing liver fibrosis/cirrhosis (p < 0.001) and inflammation (mHAI, p = 0.004). In particular, a correlation between RE and periportal or periseptal boundary zone hepatitis (moth feeding necrosis, mHAI A, p = 0.001) and portal inflammation (mHAI D, p < 0.001) was observed. In multiple linear regression analysis, both the degree of inflammation and the degree of fibrosis were significant predictors for RE (p < 0.01). Conclusion The results of this study suggest that the MR-based hepatic enhancement index RE is not only influenced by the degree of fibrosis, but also by the degree of inflammation

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    Get PDF
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency–Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research

    Large expert-curated database for benchmarking document similarity detection in biomedical literature search

    Get PDF
    Document recommendation systems for locating relevant literature have mostly relied on methods developed a decade ago. This is largely due to the lack of a large offline gold-standard benchmark of relevant documents that cover a variety of research fields such that newly developed literature search techniques can be compared, improved and translated into practice. To overcome this bottleneck, we have established the RElevant LIterature SearcH consortium consisting of more than 1500 scientists from 84 countries, who have collectively annotated the relevance of over 180 000 PubMed-listed articles with regard to their respective seed (input) article/s. The majority of annotations were contributed by highly experienced, original authors of the seed articles. The collected data cover 76% of all unique PubMed Medical Subject Headings descriptors. No systematic biases were observed across different experience levels, research fields or time spent on annotations. More importantly, annotations of the same document pairs contributed by different scientists were highly concordant. We further show that the three representative baseline methods used to generate recommended articles for evaluation (Okapi Best Matching 25, Term Frequency-Inverse Document Frequency and PubMed Related Articles) had similar overall performances. Additionally, we found that these methods each tend to produce distinct collections of recommended articles, suggesting that a hybrid method may be required to completely capture all relevant articles. The established database server located at https://relishdb.ict.griffith.edu.au is freely available for the downloading of annotation data and the blind testing of new methods. We expect that this benchmark will be useful for stimulating the development of new powerful techniques for title and title/abstract-based search engines for relevant articles in biomedical research.Peer reviewe

    Evaluation of integrated color-coded perfusion analysis for contrast-enhanced ultrasound (CEUS) after percutaneous interventions for malignant liver lesions: First results

    No full text
    BACKGROUND: With the rising number of percutaneous ablation therapies in malignant liver lesions there is a need of reliable diagnostics after the intervention to differentiate between reactive changes and tumor. PURPOSE: To assess the success of percutaneous ablation therapies for malignant liver lesions using CEUS with perfusion analysis. MATERIAL AND METHODS: Retrospective analysis of perfusion analysis for 67 patients with 94 malignant liver lesions, treated with ablation therapies. The lesions were 70 hepatocellular carcinomas (HCC), 18 metastases, 4 cholangiocellular carcinomas (CCC), 2 lesions remained unclear. CEUS was performed after bolus injection of 1.6-2.4 ml of sulfur-hexafluoride microbubbles. The perfusion analysis was calculated using Peak, TTP, mTT and AUC with integrated software during the late arterial to early portal-venous phase for approximately 9 sec (5-15 sec). For the evaluation of the success after percutaneous treatment the perfusion results were compared to the follow-up control after 6 months with CT and MRI and CEUS. RESULTS: Perfusion analyses after percutaneous treatment of malignant liver lesions showed highly significant perfusion differences when comparing the center to the surrounding tissue and the margins (p < 0.0001) for Peak and also for AUC. 62 lesions were successfully treated, meaning there was no local recurrence after 6 months. In cases of residual tumor CEUS showed a nodular marginal enhancement, the corresponding perfusion analyses showed nodular red and yellow pseudo-color shades. CONCLUSIONS: Using CEUS and perfusion analysis, a critical analysis of post-ablation defects in malignant liver lesions is possible. With the help of pseudo-colors, remaining tumor-vascularization can be detected

    Stereotactically navigated percutaneous microwave ablation (MWA) compared to conventional MWA: a matched pair analysis

    No full text
    PurposeTo compare CT-navigated stereotactic microwave ablation (SMWA) to non-navigated conventional MWA (CMWA) for percutaneous ablation of liver malignancies.MethodsA matched pair analysis of 36 patients who underwent MWA of primary or secondary liver malignancies (10 hepatocellular carcinoma and 8 metastases) was conducted. A total of 18 patients undergoing SMWA were included in this prospective study. Patients were matched in terms of tumor size, liver segment and entity to retrospective CMWA procedures. The endpoints were procedure time, accuracy of needle placement, technical success rate, complication rate and dose-length product (DLP).ResultsThe procedure durations were 23.9 min (SD 3.7) for CMWA and 21.8 min (SD 16.3) for SMWA (p = 0.22). The procedural accuracy for SMWA and CMWA was identical for both groups (3.7mm). The total DLP was significantly lower for SMWA than for CMWA (2115 mGycm (SD 276) vs. 3109 mGycm (SD 1137), respectively; p<0.01). Complete ablation without residual tumor was observed in 94% (17 of 18) of SMWA and in 83% (15 of 18) of CMWA patients (p = 0.31). No complications occurred.ConclusionsSMWA is highly accurate and reduces the radiation dose without increasing the procedure time

    Komplexität von PEComen

    No full text
    Perivascular epithelioid cell neoplasms (PEComas) are afamily of mesenchymal neoplasms with features of both melanotic and smooth muscle differentiation. PEComa morphology is highly variable and encompasses epithelioid to spindle cells often with clear cytoplasm and prominent nucleoli. Molecularly, most PEComas are defined by aloss of function of the TSC1/TSC2 complex. Additionally, adistinct small subset of PEComas harboring rearrangements of the TFE3 (Xp11) gene locus has been identified. By presenting aseries of three case reports with distinct features, we demonstrate diagnostic pitfalls as well as the importance of molecular work-up of PEComas because of important therapeutic consequences
    corecore